- Self-drilling hex and wafer-head screws
- Hold-downs and tension anchors
- Flat strap bracing with tensioners
- Clips, brackets and truss tie-downs
- Chemical, screw or wedge anchors to the slab
- Fixing schedules per panel
Connections carry the loads
In LGS the connections are as important as the members: screws join studs to tracks and truss members at nodes; hold-downs and anchors take uplift and overturning from braced walls; straps and brackets tie trusses to walls.
| Connector | Use |
|---|---|
| 10g – 14g self-drilling screws | Member to member |
| Hold-down + anchor rod | Braced wall ends to slab |
| Strap + tensioner | Diagonal wall bracing |
| Truss tie-down bracket | Roof uplift to wall |
| Anchors (chemical / screw) | Bottom track to slab |
Anchors
Bottom tracks and hold-downs are anchored to the slab with chemical anchors, concrete screws or cast-in bolts, designed for uplift and shear.
시장별 표준 및 요구사항
World Steel이 본 제품의 설계, 제작, 문서화에 적용하는 기준 – 그리고 각 시장의 주요 형상 및 하중 요구사항.
미국
- AISI S100Cold-formed steel structural members
- AISI S240Cold-formed steel structural framing
- ASTM A1003 / C955Sheet steel and load-bearing studs
- IBC Ch. 22Steel – cold-formed framing
- Coating
- G60 (Z180) minimum for structural framing members
호주 / 뉴질랜드
- AS/NZS 4600Cold-formed steel structures
- NASH StandardResidential and low-rise steel framing, Parts 1 & 2
- AS 1397Steel sheet and strip – G550, Z / AZ coatings
- NCCBuilding Code of Australia
- Corrosion
- coating class to NASH / AS 4312 exposure
유럽
- EN 1993-1-3Cold-formed members and sheeting
- EN 1090-4Execution of cold-formed structural elements
- EN 10346Continuously hot-dip coated steel – S350GD – S550GD
- EN 1993-1-1General rules
- CE
- EN 1090-1 for structural kits
참고용 요약입니다 – 프로젝트 시방서, 채택된 기준 판본 및 관할 기관의 요구가 우선합니다.
표면 처리
| 표면 처리 | 표준 / 비고 |
|---|---|
| Fasteners | Class 3 / 4 coating, stainless |