신뢰 구축, 성공 보장 고객 포털 dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Exterior-grade intumescent systems – illustration

제품 이미지: 제조사(공식).

Intumescent · exterior exposure

Exterior-grade intumescent systems

Steel outside the building envelope needs an intumescent system proven to keep its fire performance after weathering.

Exterior / semi-exposed
Exposure
EAD 350402 type X or Y
Durability
Primer + intumescent + topcoat
System

견적 요청

World Steel이 철골 건축물과 함께 또는 단독으로 공급 – 하나의 주문, 하나의 선적, 하나의 파트너.

개요

Exterior-grade intumescent systems 소개

The European assessment document EAD 350402 classifies reactive coatings for durability: type X for all conditions including exterior, type Y for internal and semi-exposed, Z1 and Z2 for internal conditions; EN 16623 sets durability requirements as well.

Exterior systems are usually solvent-based or epoxy intumescents with a compatible sealer or topcoat; the whole system – primer, basecoat and topcoat – is what was tested.

Corrosion protection of the steel underneath follows ISO 12944 for the environment.

주요 장점

  • Proven fire performance after weathering
  • Protects exposed steel and canopies
  • Works with ISO 12944 corrosion systems
  • Shop or site application

World Steel · 건물 외피 허브

철골 건축물에서의 Exterior-grade intumescent systems 활용 방식

World Steel specifies the full coating system from blast cleaning to topcoat and applies it in the shop where practical.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01구조물과 함께 사양 결정 – 두께, 밀도, 면재를 지붕, 벽 및 내화 설계에 맞춥니다.
  • 02철골, 퍼린, 외장재와 동일한 3D 모델에서 물량을 산출합니다.
  • 03철골 패키지와 함께 포장·선적 – 현장까지 하나의 납품 일정.

용도

Exterior-grade intumescent systems의 사용처

  • External steel frames and canopies
  • Open car parks and walkways
  • Semi-exposed industrial structures

기술 데이터

Exterior-grade intumescent systems – 기술 특성

Typical properties and standards

특성단위값
Durability—EAD 350402 types X / Y / Z1 / Z2 · EN 16623
Fire test—EN 13381-8 · UL 263 · BS 476-20/21 · AS 1530.4
Corrosion—ISO 12944 primer and topcoat compatible with the intumescent

해당 시장용으로 제조사가 공개한 값입니다. 주문 전 항상 최신 데이터 시트와 프로젝트에 필요한 승인 사항을 확인하세요.

FAQ

자주 묻는 질문

Can an interior intumescent be used outside with a topcoat?

Only if that complete system has been tested for exterior durability – otherwise choose an exterior-qualified system.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.

구조와 외피를 위한 하나의 파트너

도면 또는 물량 내역서를 보내주시면 철골, 단열재, 보드, 천장재를 함께 견적하여 하나의 패키지로 선적합니다.

견적 요청 +84 902 881 833