建立信任,确保成功 客户门户 dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success
Exterior-grade intumescent systems – illustration

产品图片:制造商(官方)。

Intumescent · exterior exposure

Exterior-grade intumescent systems

Steel outside the building envelope needs an intumescent system proven to keep its fire performance after weathering.

Exterior / semi-exposed
Exposure
EAD 350402 type X or Y
Durability
Primer + intumescent + topcoat
System

索取报价

由 World Steel 随您的钢结构建筑一并供应或单独供应 – 一份订单、一次发运、一个合作伙伴。

概览

关于Exterior-grade intumescent systems

The European assessment document EAD 350402 classifies reactive coatings for durability: type X for all conditions including exterior, type Y for internal and semi-exposed, Z1 and Z2 for internal conditions; EN 16623 sets durability requirements as well.

Exterior systems are usually solvent-based or epoxy intumescents with a compatible sealer or topcoat; the whole system – primer, basecoat and topcoat – is what was tested.

Corrosion protection of the steel underneath follows ISO 12944 for the environment.

主要优势

  • Proven fire performance after weathering
  • Protects exposed steel and canopies
  • Works with ISO 12944 corrosion systems
  • Shop or site application

World Steel · 建筑围护材料中心

我们如何在钢结构建筑中使用Exterior-grade intumescent systems

World Steel specifies the full coating system from blast cleaning to topcoat and applies it in the shop where practical.

Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.

  • 01与结构一同选型 – 厚度、密度和饰面与屋面、墙面及防火设计相匹配。
  • 02工程量取自与钢构件、檩条和围护板相同的 3D 模型。
  • 03与钢结构包一同包装发运 – 一份到场交货计划。

应用

Exterior-grade intumescent systems的应用场合

  • External steel frames and canopies
  • Open car parks and walkways
  • Semi-exposed industrial structures

技术数据

Exterior-grade intumescent systems – 技术性能

Typical properties and standards

性能单位数值
Durability—EAD 350402 types X / Y / Z1 / Z2 · EN 16623
Fire test—EN 13381-8 · UL 263 · BS 476-20/21 · AS 1530.4
Corrosion—ISO 12944 primer and topcoat compatible with the intumescent

数值为制造商针对该市场公布的数据。订货前请务必核对最新数据表及项目所需的认证。

FAQ

常见问题

Can an interior intumescent be used outside with a topcoat?

Only if that complete system has been tested for exterior durability – otherwise choose an exterior-qualified system.

Is this product certified?

Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.

结构与围护,一个合作伙伴

发送图纸或工程量清单 – 我们为钢结构、保温材料、板材和吊顶统一报价,并作为一个包发运。

索取报价 +84 902 881 833