Intumescent · exterior exposure
Exterior-grade intumescent systems
Steel outside the building envelope needs an intumescent system proven to keep its fire performance after weathering.
- Exterior / semi-exposed
- Exposure
- EAD 350402 type X or Y
- Durability
- Primer + intumescent + topcoat
- System
World Steel が鉄骨建築と一括で、または単体で供給 – 一つの注文、一つの出荷、一つのパートナー。
概要
Exterior-grade intumescent systemsについて
The European assessment document EAD 350402 classifies reactive coatings for durability: type X for all conditions including exterior, type Y for internal and semi-exposed, Z1 and Z2 for internal conditions; EN 16623 sets durability requirements as well.
Exterior systems are usually solvent-based or epoxy intumescents with a compatible sealer or topcoat; the whole system – primer, basecoat and topcoat – is what was tested.
Corrosion protection of the steel underneath follows ISO 12944 for the environment.
主なメリット
- Proven fire performance after weathering
- Protects exposed steel and canopies
- Works with ISO 12944 corrosion systems
- Shop or site application
World Steel · 外装材ハブ
鉄骨建築におけるExterior-grade intumescent systemsの活用
World Steel specifies the full coating system from blast cleaning to topcoat and applies it in the shop where practical.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01構造と一体で仕様決定 – 厚さ、密度、表面材を屋根・外壁・耐火設計に合わせます。
- 02数量は鉄骨、母屋、外装材と同じ 3D モデルから算出。
- 03鉄骨パッケージとともに梱包・出荷 – 現場への納入スケジュールは一つです。
用途
Exterior-grade intumescent systemsの用途
- External steel frames and canopies
- Open car parks and walkways
- Semi-exposed industrial structures
技術データ
Exterior-grade intumescent systems – 技術特性
Typical properties and standards
| 特性 | 単位 | 値 |
|---|---|---|
| Durability | — | EAD 350402 types X / Y / Z1 / Z2 · EN 16623 |
| Fire test | — | EN 13381-8 · UL 263 · BS 476-20/21 · AS 1530.4 |
| Corrosion | — | ISO 12944 primer and topcoat compatible with the intumescent |
この市場向けにメーカーが公表している値です。ご注文前に必ず最新のデータシートと、プロジェクトに必要な認定をご確認ください。
FAQ
よくある質問
Can an interior intumescent be used outside with a topcoat?
Only if that complete system has been tested for exterior durability – otherwise choose an exterior-qualified system.
Is this product certified?
Certification belongs to a specific manufacturer’s product or tested system. We supply the test report, classification or listing accepted in your market for the product selected – it is confirmed per project, never assumed.