Xây dựng niềm tin, Bảo đảm thành công Cổng khách hàng dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

Kỹ thuật chống cháy · bài 2/10

How does intumescent paint work?

From a thin film to an insulating char: the chemistry and physics of intumescent coatings in a fire, and why expansion and performance are specific to each product.

Đội ngũ kỹ sư World Steel · Cập nhật 2026-10-16 · 2 phút đọc

Intumescent coating expanding into char (illustration)

Three ingredients working together

A typical intumescent formulation contains an acid source (often a phosphate), a carbon source (a polyol) and a blowing agent (for example a melamine compound), held in a binder that softens when heated.

  1. The binder softens and the acid source decomposes.
  2. The acid reacts with the carbon source to form a carbon-rich char.
  3. The blowing agent releases gases that foam the softened mass.
  4. The result is a thick, porous char with low thermal conductivity.

The degree of expansion, the char strength and the insulation are specific to each product and are only known from its fire tests.

What the char does

The char is an insulating blanket between the fire and the steel. Heat still passes through, but much more slowly, so the steel temperature rises gradually. The coating is designed so that the steel stays below its critical temperature for the rated time.

Cellulosic and hydrocarbon fires

Building fires follow the standard (cellulosic) fire curve – ISO 834, ASTM E119, AS 1530.4. Hydrocarbon pool fires heat up much faster and hotter (UL 1709, EN 1363-2), and jet fires add erosion. Thin-film building intumescents are not designed for these conditions – epoxy systems tested for hydrocarbon and jet fires are.

What decides performance

  • Dry film thickness – more coating, more char.
  • Section factor – how fast the member heats up.
  • Critical steel temperature – the target the steel must stay below.
  • Section shape – open sections and hollow sections are tested separately.

FAQ

At what temperature does intumescent coating start to expand?

Typically from around 200–250 °C, but the exact activation temperature depends on the product.

Does the char fall off?

A correctly applied and certified system keeps a stable char for the tested duration; char stickability is part of the fire test.

Cần độ dày và chi phí cho dự án của bạn?Gửi danh sách cấu kiện và cấp chịu lửa – kỹ sư của chúng tôi lập đề xuất chống cháy.
Yêu cầu đề xuất

Preliminary calculations are provided for estimation purposes only. Final coating thickness and fire protection system selection must be verified against the approved product documentation, applicable project requirements and relevant engineering assessments.

Dự án tiếp theo

Bạn đang lên kế hoạch cho công trình kết cấu thép ở nước ngoài?

Gửi cho chúng tôi bản vẽ hoặc mô hình IFC – bộ phận dự toán sẽ phản hồi phạm vi gia công, tiến độ và giá giao hàng.