建立信任,确保成功 客户门户 dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

Design & engineering

Structural optimisation with tapered sections

Structural optimisation of PEB frames with tapered built-up sections: how web depth follows the moment diagram, design checks, limits and steel savings drivers.

更新于 4 分钟阅读 在 3D 模型中查看 →

Tapered PEB portal frame whose depth varies to follow the bending moment diagram
Tapered members put steel where the bending moment is highest.

The optimisation principle

In a rigid portal frame the bending moment varies strongly along each member: high at the knee and ridge, lower in between, and near zero at a pinned base. A hot-rolled section has the same depth everywhere and is therefore oversized for most of its length. A tapered built-up member, welded from three plates, can vary web depth, web thickness and flange size along its length to follow the moment diagram. This is the core idea of the pre-engineered building: material is placed only where it is needed. Combined with high-strength steel (typically 345–355 MPa yield) and thin webs, tapered frames commonly use substantially less steel than equivalent frames in uniform hot-rolled sections, though the saving depends on span, loads and serviceability limits.

Elevation and section of a tapered built-up I-member
Tapered built-up member: variable web depth, plate flanges, fillet welded.

What gets optimised

Optimisation variables in a PEB frame
VariableTypical approach
Web depthTapered columns (shallow at pinned base, deep at knee); rafters deep at knee, shallower at mid-span, deeper again at ridge
Web thicknessThin, often slender webs (about 4–10 mm), checked for shear buckling and web crippling
Flange sizeWidth and thickness changed at splices and along the member
Member segmentationSplice locations chosen for transport length and moment
Bracing pointsFlange braces from purlins and girts reduce unbraced length of the inner flange
Frame geometryRoof slope, bay spacing and interior columns compared for total weight
Base fixityPinned bases favoured for foundation economy

Design checks for tapered members

Tapered, slender members require checks beyond those for compact hot-rolled sections:

  • Local buckling and slender webs: AISC 360-22 (with AISC Design Guide 25 for web-tapered members), AS 4100:2020, CSA S16-19 and EN 1993-1-5 provide rules for slender plate elements and shear buckling, including tension field action where permitted.
  • Lateral-torsional buckling: of the unbraced inner flange in negative moment regions near knees, governed by flange brace spacing.
  • Stability analysis: second-order (P-Δ) effects using the direct analysis method (AISC 360-22) or equivalent amplification in AS 4100 and EN 1993-1-1.
  • Web-to-flange welds: sized for shear flow; one-sided fillets are common where design and code permit.
  • Serviceability: lighter frames are more flexible – see serviceability and deflection limits.

AISC Design Guide 25 (Frame Design Using Nonprismatic Members) and the MBMA Metal Building Systems Manual are key references for US practice.

Building parameters that drive steel weight

Member-level optimisation only works within the geometry the owner chooses. The largest savings are usually made earlier, when the building parameters are set:

How building parameters affect steel weight (general tendencies)
ParameterEffectPractical guidance
Clear spanFrame moments rise roughly with the square of the spanAbove about 40–50 m, compare with one or more interior columns
Bay spacingWider bays mean fewer frames but heavier purlins and girtsAbout 7.5–9 m is often economical; longer bays with jack beams or deeper purlins
Eave heightHigher eaves increase wind moments and column sizeSet from the real clearance need, not a round number
Roof slopeVery flat roofs increase rafter moments and deflection; steep roofs add wall and cladding areaAbout 1:10 to 1:20 suits most frames
Column basesFixed bases reduce frame weight and drift but enlarge footingsPinned bases unless drift or cranes demand fixity
Load allowancesOver-generous collateral or live loads add weight to every frameSpecify real services loads; add allowances for known future equipment only
EndwallsRigid endwall frames weigh more than post-and-beamUse rigid endwalls only where expansion is planned

Because these choices interact, World Steel's estimators usually price two or three alternatives – for example clear span versus one interior column, or 7.5 m versus 9 m bays – before the design criteria are frozen. The relevant systems are described in clear-span and multi-span buildings.

Limits of optimisation

Optimising for weight alone can increase cost. Very thin webs need more stiffeners and careful handling; many plate thickness changes raise fabrication and welding effort; very slender frames may fail drift limits or vibrate. A good PEB design balances steel weight, fabrication labour, transport (member lengths and container fit), erection simplicity and foundation cost. Optimisation of purlins and girts – lapped Z sections, gauge changes by zone – adds further savings in secondary framing.

How WSC applies optimisation

World Steel designs frames with dedicated PEB software and its in-house engineers, then fabricates the tapered members on automatic welding lines (see automatic welding of built-up members). Designs follow the client's code and serviceability criteria; optimisation is never allowed to override code checks. Typical steps are: agree design criteria and serviceability limits; run a first analysis with standard member depths; iterate web depth, plate thicknesses and splice positions; position flange braces to suit the purlin and girt layout; and finally rationalise plate sizes so that the shop can nest web plates efficiently from standard plate widths and minimise the number of different thicknesses ordered. The result is a frame that is light, but also simple to cut, weld, ship and erect. This is part of WSC's design service for pre-engineered buildings.

各地区标准

地区规范范围
United States AISC 360-22Specification for structural steel buildings
United States AISC Design Guide 25Frame design using nonprismatic members
Canada CSA S16-19Design of steel structures
Australia / NZ AS 4100:2020Steel structures
Europe EN 1993-1-1 / 1-5General rules; plated structural elements

常见问题

Why are PEB frames tapered?

Because bending moment varies along the frame. Tapering the web lets each part of the member be as deep as it needs to be, saving steel compared with a constant hot-rolled section.

Are thin webs in PEB members safe?

Yes, when designed for slender-element and shear-buckling effects per the governing code and braced as designed. Codes specifically cover slender webs and nonprismatic members.

Is the lightest frame always the cheapest?

No. Fabrication labour, stiffeners, transport, erection and foundations also count, so good optimisation balances weight against these costs.

下一个项目

计划在海外建造钢结构?

请发送您的图纸或 IFC 模型——我们的报价团队将回复加工范围、工期及到岸价格。