Purlins and girts are roll-formed from high-strength galvanized or hot-rolled coil.

What cold-formed steel is

Cold-formed steel sections are shaped at room temperature from thin flat strip by roll forming or press braking. In pre-engineered buildings they form the secondary framing: Z and C purlins, girts, eave struts, door jambs and flange braces. Typical thicknesses are about 1.5–3.0 mm and depths 150–350 mm. Because the sections are thin, they are efficient but susceptible to local, distortional and lateral-torsional buckling, which is why they are designed to dedicated cold-formed codes rather than hot-rolled steel codes.

Cold-formed Z, C and eave strut sections
Common cold-formed profiles: Z, C and eave strut.

Coil types and grades

Cold-formed coil grades by region (approximate equivalents, indicative only)
TypeUSA (ASTM)Australia / NZEuropeJapan
Hot-rolled (black), ~340–380 MPaA1011 SS Grade 50 / HSLAS Grade 50–55AS/NZS 1594 HA350 / HW350EN 10149-2 S355MC–
Galvanized, ~340–350 MPaA653 SS Grade 50 (340 MPa)AS 1397 G350EN 10346 S350GD+ZJIS G3302 SGC440
Galvanized, ~450 MPaA653 SS / HSLAS Grade 60–70 (approx.)AS 1397 G450EN 10346 S450GD+Z–
Galvanized, ~550 MPaA653 SS Grade 80 (550 MPa)AS 1397 G550EN 10346 S550GD+ZJIS G3302 SGC570

Very high-strength grades (G550, Grade 80) usually have limited elongation; codes reduce the design strength or restrict their use in some applications (for example AS/NZS 4600 and AISI S100 provisions for low-ductility steels). Purlins in Australia are commonly G450 with Z350 coating, while US metal building purlins are often Grade 55 hot-rolled or galvanized material.

Galvanized or black steel?

  • Pre-galvanized (Z) coil: zinc coating applied at the mill (e.g. Z275 / G90 in US terms, Z350 in Australia); sections are punched after forming with cut edges protected by the zinc's sacrificial action. Good durability for enclosed buildings; no painting required.
  • Hot-rolled black coil: lower material cost; shop primed or painted after forming. Common in North American metal buildings and for dry interior environments.
  • Hot-dip galvanized after forming: heavy coating for agricultural or corrosive buildings.
  • ZAM (Zn-Al-Mg) coil: increasingly used for improved cut-edge and coastal performance at lower coating mass – see metallic-coated sheet.

Choose the coating to the building's environment: open-sided, livestock, coastal and chemical environments need heavier protection than closed warehouses.

Design codes and fabrication

Cold-formed members are designed to AISI S100-16 (reaffirmed 2020) in the US, CSA S136-16 in Canada, AS/NZS 4600:2018 in Australia and New Zealand and EN 1993-1-3 in Europe. Section capacities depend on the effective width method or the direct strength method, and purlin systems benefit from lapping over supports (see purlins). Base metal thickness (BMT), not total coated thickness, is used in design and must be checked on delivery. Coil is ordered by grade, coating mass, width and BMT; incoming coils are checked against the mill certificate for yield strength, coating mass and thickness tolerance before roll forming. Punching of holes for bolts, sag rods and bracing is done inline, so hole positions must match the purlin and girt layout exactly. Because the section is thin, handling, bundling and storage on site matter: bundles should be kept dry and ventilated to avoid white rust on galvanized material. Roll-forming, punching and cutting are covered in cold roll forming.

Material requirements, testing and acceptance

Cold-formed design codes assume a minimum level of ductility and accurate thickness, so incoming coil is checked against more than just the grade name.

Typical acceptance checks for cold-formed coil
PropertyTypical requirement or methodReference examples
Yield and tensile strengthTensile test per heat or coil, compared with the grade minimumASTM A370, ISO 6892-1, AS 1391
DuctilityRatio of tensile to yield strength and elongation above code minimums (for example Fu/Fy of at least about 1.08 with about 10% elongation in AISI S100); low-ductility steels attract reduced design valuesAISI S100-16, AS/NZS 4600:2018, EN 1993-1-3
Base metal thicknessMeasured after removing coating, or calculated from total thickness minus coating; tolerances per product standardASTM A924, AS 1397, EN 10143
Coating massTriple-spot and single-spot tests or calibrated gaugesASTM A90, AS 1397, EN 10346
Surface conditionNo white rust, laminations, edge cracks or excessive camberVisual inspection on receipt

For galvanized purlins, typical coating masses are Z275 (G90) for enclosed industrial buildings and Z350–Z450 or Zn-Al-Mg coatings for humid, open-sided or near-coastal buildings. Where a heavier coating is not available on coil, hot-dip galvanizing after fabrication to ISO 1461, ASTM A123 or AS/NZS 4680 is an option, but it adds cost and can cause distortion in thin sections.

Sources and WSC supply

Galvanized coil for purlins is produced in Vietnam by coated-steel mills and also imported; hot-rolled coil is produced by integrated mills such as Hoa Phat, Formosa Ha Tinh and China Steel Sumikin Vietnam. World Steel roll-forms Z and C sections in-house, selecting grade and coating to suit the destination code and environment, and supplies them as part of its secondary members package.

תקנים לפי אזור

אזורתקןהיקף
United States AISI S100-16 (2020)North American specification for cold-formed steel structural members
United States ASTM A653 / A1011Galvanized sheet; hot-rolled sheet and strip
Canada CSA S136-16Canadian edition of the North American cold-formed specification
Australia / NZ AS/NZS 4600:2018Cold-formed steel structures
Australia / NZ AS 1397Continuous hot-dip metallic coated steel sheet and strip
Europe EN 1993-1-3Cold-formed members and sheeting
Europe EN 10346Continuously hot-dip coated steel flat products

שאלות נפוצות

What steel grade is used for PEB purlins?

Typically high-strength coil of about 340–450 MPa yield, such as AS 1397 G450, EN 10346 S450GD or ASTM A653 / A1011 Grade 50–55, either pre-galvanized or hot-rolled and primed.

Are galvanized purlins better than painted black purlins?

Pre-galvanized purlins usually offer better long-term corrosion protection in enclosed buildings and need no painting. Primed black purlins are cheaper and suitable for dry interiors.

What is BMT?

Base metal thickness – the steel thickness excluding the metallic coating. Design and inspection of cold-formed sections use BMT.