Bâtir la confiance, garantir le succès Portail client dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

Applications

Warehouses

Why pre-engineered steel buildings suit warehouses: typical widths, clear heights and bay spacing, racking, docks, fire protection and recommended components.

Mis à jour 3 min de lecture Voir dans le modèle 3D →

Large pre-engineered steel warehouse with multi-span frames, roll-up doors and loading canopy
Warehouses are the classic PEB application – large, column-free floor area at low steel weight.

Why PEB fits warehouses

A warehouse is essentially a weather-tight envelope over a large, flat floor. The owner wants the greatest usable volume for the least cost, built quickly, with the flexibility to extend later. Pre-engineered steel buildings meet all of these: tapered frames place steel only where it is needed, cold-formed purlins and girts span efficiently between frames, and the building can be extended by adding bays at an endwall designed for future expansion. Compared with conventional hot-rolled or concrete construction, a PEB warehouse is typically lighter and faster to build – see advantages of PEB.

Typical dimensions

Diagram of building width, length, eave height, bay spacing and roof slope
Key dimensions of a warehouse PEB.
Typical warehouse PEB dimensions (indicative)
ParameterTypical rangeNotes
Width30–120 m and moreClear span up to ~60–90 m; wider buildings use multi-span frames
Eave height8–14 mSet by racking height plus sprinkler and lighting clearance
Bay spacing7.5–10 mLonger bays with heavier purlins or trusses where racking grid demands
Roof slope1:20 to 1:10Low slopes favour standing seam roofs
Interior column spacing (multi-span)Coordinated with rack and aisle layoutColumns placed within rack lines, not aisles

Special requirements

  • Racking coordination – the column grid, clear height and slab design are planned together with the racking layout. Racking is normally free-standing and not tied to the building frame unless designed for it.
  • Loading docks – dock doors, levellers, seals or shelters, and a canopy over the dock apron; framed openings are designed into the wall girts.
  • Fire protection – sprinkler systems (for example NFPA 13 or FM Global data sheets in the US, AS 2118.1 in Australia, EN 12845 in Europe) add load to purlins and influence roof height; fire separation, smoke vents and compartment limits follow the local building code.
  • Daylight and ventilation – skylights reduce lighting energy; ridge ventilators and louvers help in hot climates.
  • Floor slab – the slab is by others but the anchor bolt layout and column base reactions are supplied by the PEB manufacturer.
  • Rooftop solar – increasingly common; the additional dead load and wind uplift must be included at design stage.

Envelope and corrosion protection by climate

The same warehouse frame can be wrapped in very different envelopes depending on climate, stored goods and site exposure. The table gives typical starting points that are refined during design.

Typical warehouse envelope choices by situation (indicative)
SituationRoof and wallsInsulation and ventilationFrame protection
Hot humid tropics, general goodsAZ150 sheet with polyester or SMP paint, light coloursGlass wool blanket with foil facing or reflective foil; ridge vents and low louversShop primer plus finish for ISO 12944 C2–C3
Coastal site within a few kilometres of the seaAZ200 or Zn-Al-Mg with HDP or PVDF; Class 4 or stainless fastenersAs above; avoid trapping salt-laden air at eavesZinc-rich system for C4, or galvanized secondary steel with heavier coating
Temperate or cold climate, heatedInsulated sandwich panels or double-skin roof with linerContinuous vapour retarder; energy-code R-valuesC2 system for the warm, dry interior
Fertiliser, salt or chemical storageAluminium, GRP or heavy-duty coated sheet; plastisol linersMinimal insulation; strong ventilationHot-dip galvanizing or duplex system, sealed details

Specify the corrosivity category for the interior and the exterior separately: a closed warehouse interior is often C2 even when the coastal exterior is C4. See metallic-coated sheet and paint and coating systems for selection details.

World Steel warehouse supply

World Steel designs and fabricates complete warehouse buildings as pre-engineered buildings, from frames and secondary members to cladding and accessories, for industrial and commercial clients. Design follows the code of the destination – ASCE 7 and AISC in the United States, AS/NZS 1170 and AS 4100 in Australia, Eurocodes in Europe. See also logistics and distribution centres for high-throughput facilities.

Normes par région

RégionNormePérimètre
United States ASCE 7-22 / IBC 2024 / NFPA 13Loads; building code (storage occupancy); sprinkler systems
Canada NBC 2020 / CSA S16-19National Building Code; steel design
Australia / NZ NCC / AS/NZS 1170 / AS 4100:2020Building code; loads; steel structures
Europe EN 1991 / EN 1993-1-1 / EN 12845Actions; steel design; sprinkler systems

Questions fréquentes

What is the maximum clear span for a PEB warehouse?

Clear spans of 60–90 m are achievable with tapered frames, but cost per square metre usually rises beyond about 40–50 m. Wide warehouses are often more economical as multi-span buildings with interior columns placed in rack lines.

How high should a warehouse eave be?

It is set by the top of racking plus clearances for sprinklers, lighting and the roof structure. Typical PEB warehouses have eave heights of 8–14 m.

Can a PEB warehouse be extended later?

Yes. Designing one endwall as an expandable frame allows additional bays to be added with minimal disruption.

Prochain projet

Un projet de structure métallique à l'étranger ?

Envoyez-nous vos plans ou votre maquette IFC – notre équipe de chiffrage vous répond avec le périmètre de fabrication, le planning et le prix rendu chantier.