Bâtir la confiance, garantir le succès Portail client dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

Light gauge steel framing

LGS load-bearing wall panels

Prefabricated load-bearing LGS wall panels – studs at 400 / 600 mm, tracks, noggings, lintels and strap or sheet bracing – for houses and mid-rise buildings.

États-UnisAustralie / NZEurope

Demander un devis Caractéristiques

  • Panels assembled flat, delivered ready to stand
  • Studs at 400 / 600 mm, stud over stud
  • Lintels, jamb studs and cripples at openings
  • Strap or sheet bracing for wind and seismic
  • Hold-downs and anchors to the slab
  • Openings and services set out from the model

How a wall panel works

Vertical loads flow down the studs to the bottom track and the slab; lateral loads from wind and earthquakes are carried by braced panels – diagonal steel straps or structural sheathing – into hold-downs and anchors. Openings are framed with jamb studs and a lintel.

A light gauge steel building, part by part
From slab anchors to roof sheeting.

Panel components

Wall panel members
MemberTypical sectionNotes
StudsC 89 – 150, 0.75 – 1.6 mm400 / 600 mm centres
Top and bottom tracksU to suit studscrew-fixed to each stud
Noggings / bridgingC or Umid-height restraint and fixings
Lintelsback-to-back C, boxedover doors and windows
Bracingflat strap or sheathingwith tensioners and hold-downs
Anchorschemical / mechanical / cast-into concrete slab or steel beam

Envelope

Wall build-up
Each layer has a job.

Fire, acoustic and thermal performance come from the tested lining and insulation system around the frame – we detail the walls to the board and insulation manufacturers' tested systems.

Normes et exigences par marché

Les codes selon lesquels World Steel conçoit, fabrique et documente ce produit – et les principales exigences géométriques et de charge sur chaque marché.

États-Unis

  • AISI S100Cold-formed steel structural members
  • AISI S240Cold-formed steel structural framing
  • ASTM A1003 / C955Sheet steel and load-bearing studs
  • IBC Ch. 22Steel – cold-formed framing
Coating
G60 (Z180) minimum for structural framing members
Toutes les normes United States →

Australie / NZ

  • AS/NZS 4600Cold-formed steel structures
  • NASH StandardResidential and low-rise steel framing, Parts 1 & 2
  • AS 1397Steel sheet and strip – G550, Z / AZ coatings
  • NCCBuilding Code of Australia
Corrosion
coating class to NASH / AS 4312 exposure
Toutes les normes Australia & New Zealand →

Europe

  • EN 1993-1-3Cold-formed members and sheeting
  • EN 1090-4Execution of cold-formed structural elements
  • EN 10346Continuously hot-dip coated steel – S350GD – S550GD
  • EN 1993-1-1General rules
CE
EN 1090-1 for structural kits
Toutes les normes Europe →

Synthèse fournie à titre indicatif – le cahier des charges du projet, l'édition du code adoptée et l'autorité compétente prévalent.

Finitions

FinitionNormes / remarques
FrameZ275 / AZ150 coated

Prochain projet

Un projet de structure métallique à l'étranger ?

Envoyez-nous vos plans ou votre maquette IFC – notre équipe de chiffrage vous répond avec le périmètre de fabrication, le planning et le prix rendu chantier.