Fire-rated panels · compartment walls
Fire compartment wall systems
A fire wall must stay standing and intact while the building on one side burns – the panel, its fixings and the steel that holds it are designed as one system.
- Stone wool, higher density
- Core
- Compartment and boundary walls
- Use
- Per tested system and code
- Rating
由 World Steel 随您的钢结构建筑一并供应或单独供应 – 一份订单、一次发运、一个合作伙伴。
概览
关于Fire compartment wall systems
Compartment walls in steel buildings are often panel systems on their own steel frame, so that the collapse of the burning side does not pull the wall down.
The required rating, the structural fire design of the supporting steel and the treatment of roof junctions are set by the fire engineer and the local code.
Openings in the wall need fire-rated doors, shutters or curtains, and every service penetration needs a tested seal.
主要优势
- Limits fire spread between compartments
- Lighter and faster than masonry
- Tested panel joints and fixings
- Integrates doors, shutters and seals
World Steel · 建筑围护材料中心
我们如何在钢结构建筑中使用Fire compartment wall systems
World Steel designs and fabricates the supporting steel of the fire wall together with the main structure and coordinates the panel system to the fire engineer’s design.
Product-specific test reports, classification reports and certificates are supplied for the product selected for each project – this page describes the product type, not a certified product.
- 01与结构一同选型 – 厚度、密度和饰面与屋面、墙面及防火设计相匹配。
- 02工程量取自与钢构件、檩条和围护板相同的 3D 模型。
- 03与钢结构包一同包装发运 – 一份到场交货计划。
应用
Fire compartment wall systems的应用场合
- Large warehouses and logistics centres
- Factories with high fire loads
- Boundary walls close to other buildings
技术数据
Fire compartment wall systems – 技术性能
Typical properties and standards
| 性能 | 单位 | 数值 |
|---|---|---|
| Fire resistance | — | EN 1364-1 / EN 13501-2 (EI, EI-M where impact is required) · ASTM E119 · AS 1530.4 |
| Supporting steel | — | Designed for the fire scenario per EN 1993-1-2 / AS 4100 / AISC 360 App. 4 |
| Openings | — | Fire doors, shutters, curtains – tested with the wall type |
| Penetrations | — | Firestop systems tested for panel walls |
数值为制造商针对该市场公布的数据。订货前请务必核对最新数据表及项目所需的认证。
Fire-rated panels
相关产品
Fire-rated panels · wallsStone wool sandwich wall panels查看产品 →
Fire-rated panels · roofsStone wool sandwich roof panels查看产品 →
Fire-rated panels · interiorsFire-rated partition and ceiling panels查看产品 →← Fire-rated sandwich panelsFire-Rated Building Systems – Panels, Doors, Glazing, Shutters and Curtains →
FAQ
常见问题
Who designs the fire wall?
The fire engineer sets the rating and strategy; World Steel designs the supporting steel and coordinates the tested panel system and openings.
Is this product certified?