信頼を築き、成功を確かなものに クライアントポータル dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

WS modular homes

WS modular building system

The WS module: a 12.0 × 4.5 × 3.1 m galvanised Q355 steel frame with floor, walls, roof, bathroom pod and services – the base of every WS home.

豪州 / NZ米国欧州

見積もりを依頼 仕様

  • One module, five homes
  • 12.0 × 4.5 × 3.1 m · 54 m²
  • Galvanised Q355 steel frame
  • Base, Fire-rated and Project-custom variants
  • Up to ≈ 91 % factory completion
  • 4–6 weeks production

One platform for every home

Every WS modular home is built from the same module: a galvanised Q355 steel frame 12.0 m long, 4.5 m wide and 3.1 m high, with its floor, walls, roof, bathroom pod, services and finishes installed in the factory. Modules are combined side by side, end to end and stacked two storeys to make studios, cabins, family homes and courtyard houses.

The WS module, 12.0 x 4.5 x 3.1 m
The WS module – one platform for every model.
The five WS modular home models
The WS modular range.

Module variants

Base, fire-rated and project-custom module specifications
WS-ML-01 Base, WS-ML-02 Fire-rated and Project custom.
WS module variants
WS-ML-01 BaseWS-ML-02 Fire-ratedProject custom
Module size12.0 × 4.5 × 3.1 m12.0 × 4.5 × 3.1 mCustom dimensions available
Fire ratingNon-fire-rated (standard)FRL 60/60/60 target (structural / walls / roof)Tailored to project requirements
Structural frameGalvanised steel frame (Q355)Galvanised steel frame with fire protectionEngineered to project specifications
Floor system18 mm flooring board + insulationFire-rated flooring system + insulationCustom floor build-up as specified
Wall systemInsulated sandwich panel (75 / 100 mm)Fire-rated wall panels (FRL 60/60/60 target)Cladding and insulation options to suit
Roof / envelopeInsulated roof panel + membraneFire-rated roof system + membraneRoofing and facade options to suit
Bathroom corePre-fitted wet room pod (plumbing & drainage)Fire-rated wet room pod with fire dampersPod or custom solution as specified
Interior finishStandard lining & paint, vinyl plank flooringFire-rated linings & doors, vinyl plank flooringFinishes, fixtures & fittings to project scope
ApplicationStandard residential or accommodation useApplications requiring enhanced fire performanceBespoke applications per project
Compliance pathwayEngineered to NCC requirementsNCC and FRL engineering, evidence per projectPerformance solutions and certification to project

FRL ratings are achieved with tested or assessed systems and confirmed for each project by the building certifier; the variant names the design target.

Build-up

Module build-up: structure, floor, walls, roof, wet core, services
Module build-up.
  • Steel frame – galvanised Q355 frame engineered for strength, precision and durability, with corner posts for lifting and stacking.
  • Wet core – factory-built bathroom pod for quality and consistency.
  • MEP rough-in – services pre-installed for fast connection on site.
  • External envelope – high-performance thermal and weather protection.
  • Interior fit-out – finishes designed for comfort and function.
  • Dispatch ready – inspected, wrapped and ready for safe transport.

Factory to site

Modular production flow from frame to site set
From frame to finished home.

Frames are welded on jigs in World Steel's certified structural steel plant – the same welding procedures and inspection as our structural work under ISO 3834-2 and AS/NZS 5131. Each module is tested, inspected, wrapped and dispatched; on site it is craned onto prepared footings and connected to services.

At 4.5 m wide a module is an over-width road load: transport permits, escorts and the route are planned with the logistics partner. Sea freight is on flat racks or break-bulk.

市場別の規格と要求事項

World Steelが本製品の設計・製作・書類作成に適用する基準――および各市場における主な寸法・荷重要件。

豪州 / NZ

  • NCC 2022 Vol. 1 & 2Building Code of Australia – Class 1a / 2 / 3 as applicable
  • AS/NZS 1170Structural design actions incl. wind regions
  • AS 4100 · AS/NZS 4600Steel and cold-formed steel structures
  • AS 1530.4Fire-resistance tests – FRL
  • AS 3740Waterproofing of domestic wet areas
  • AS/NZS 3000 · AS/NZS 3500Electrical installations · plumbing and drainage
Fire-rated variant
FRL 60/60/60 target with tested or assessed systems
Approval
Building certifier per state; transport permits per route
Australia & New Zealandの規格一覧 →

米国

  • IBC / IRCInternational Building / Residential Code
  • ICC/MBI 1200 & 1205Off-site construction: planning, inspection, regulatory compliance
  • ASCE 7 · AISC 360Loads and steel design
  • NEC · IPCElectrical and plumbing codes
Approval
State modular / industrialised building program where applicable
United Statesの規格一覧 →

欧州

  • EN 1990 – EN 1993Eurocodes – basis, actions, steel
  • EN 13501-2Fire resistance classification (REI)
  • EN 1090-2 WSC認証取得Execution of steel structures – WS EXC3
Approval
National building rules and energy performance per country
Europeの規格一覧 →

参考用の概要です――プロジェクト仕様書、採用される基準の版、所轄官庁の判断が優先されます。

表面処理

表面処理規格 / 備考
ExteriorInsulated wall panel with charcoal frame trim; cladding options to suit
DeckTimber or composite deck to project
InteriorLining and paint, vinyl plank flooring, cabinetry and joinery
Project finishesColours, fixtures and fittings on request

よくある質問

What is the difference between Base and Fire-rated?

Base (WS-ML-01) is the standard non-fire-rated build-up for residential and accommodation use. Fire-rated (WS-ML-02) adds fire protection to the frame, fire-rated floor, wall and roof systems, fire-rated linings and doors and a pod with fire dampers, targeting FRL 60/60/60.

Can modules be stacked?

Yes – two-storey homes such as WS Family Living use stacked modules bolted at the corner posts.

How are modules transported?

Wrapped and lifted at the corner points onto low-loaders; 4.5 m width needs over-width permits. Export shipments go on flat racks or break-bulk.

次のプロジェクト

海外で鋼構造物をご計画ですか?

図面または IFC モデルをお送りください。積算チームが製作範囲、工程、納入価格をご回答します。