信頼を築き、成功を確かなものに クライアントポータル dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

WSC PEB products

Skylights and daylighting products

Skylights and daylighting products for PEB roofs and walls: GRP and polycarbonate sheets matched to the cladding profile, with safety mesh options, from WSC.

更新日 3 分で読めます 3D モデルで見る →

Translucent skylight panels in the roof of a pre-engineered steel building
Translucent panels matched to the roof profile bring daylight into the building.

Scope of supply

Daylighting reduces artificial lighting in warehouses, factories and sports halls. World Steel supplies skylights and translucent panels as part of the accessories package, matched to the profile of the roof and wall cladding so they lap and fix like the adjacent steel sheets.

  • Translucent roof sheets in the same profile as the steel roof sheet.
  • Translucent wall panels for clerestory lighting.
  • Insulated double-skin skylights where the roof is insulated.
  • Fixing screws with oversized holes or washers suited to plastic sheet, foam closures and sealant.
  • Optional safety mesh under roof skylights to protect against falls through the sheet.

Options and variants

Daylighting sheet options
MaterialTypical featuresNotes
GRP / FRP (glass-reinforced polyester)Matching profiles, UV-protected surface filmCommon for industrial roofs; diffuse light
Polycarbonate profiled sheetHigh impact resistance, UV-protected faceCheck thermal movement allowance
Multiwall polycarbonateImproved insulationUsed for walls and dedicated skylight frames
Double-skin GRPLiner and outer sheet with spacerMatches insulated roofs, reduces condensation

Typical daylighting ratios are about 5–10% of roof area, decided by the lighting designer to balance daylight against heat gain and glare. Fire behaviour of plastic sheets differs between materials, so local requirements govern the choice. Product brands include Ampelite and Palram.

Trapezoidal and standing seam profiles
Skylight sheets are formed to the same profile as the steel sheet.

Materials, finishes and safety

Skylight sheets are specified by weight or thickness, light transmission and UV protection. Because a translucent sheet is not a walkable surface, roof access must be controlled: safety mesh, guardrails or signage are provided as the market requires. In the United States OSHA requires protection of skylight openings during construction and maintenance; Australian work health and safety rules similarly require fall protection. See site safety during steel erection.

Compliance by market

Skylights are bought-in products; the codes below govern the product and its fixing, while WSC's certifications apply to the steel structure.

Compliance by market
MarketDesign codeFabrication / weldingMaterialsCertification notes
United StatesIBC Chapter 26 (light-transmitting plastics), ASCE 7-22 wind; OSHA 1926/1910 fall protectionNot applicable (no welding)GRP / polycarbonate with ICC-ES or manufacturer dataWSC holds IAS AC472 accreditation for metal building systems; welding qualified to AWS D1.1 (structural) and AWS D1.3 (sheet steel). AISC Certification is not held – confirm acceptance if specified.
CanadaNBC 2020 plastic glazing and fire provisionsNot applicableManufacturer-certified sheetsDesigned to CSA S16 / CSA S136 by WSC or the engineer of record. CSA W47.1 (CWB) company certification is a market requirement, arranged per project.
Australia / New ZealandAS/NZS 4256 (plastic roof and wall cladding), AS/NZS 1562.3 designAS/NZS 5131 for supporting steelGRP / PC to AS/NZS 4256WSC is certified to AS/NZS 5131 Construction Category CC3; welding to AS/NZS 1554.1. For New Zealand, SFC certification is not held – confirm acceptance per project.
EuropeEN 1013 (profiled plastic sheets), EN 14963 (rooflights)EN 1090-2 for supporting steelCE-marked products per EN 1013 / EN 14963WSC is certified to EN 1090-2 Execution Class EXC3 and ISO 3834-2. CE marking via EN 1090-1 factory production control to be confirmed per project.

Data to request for translucent products

Key properties of translucent sheets and how they are specified
PropertyTypical referenceWhy it matters
Light transmission and hazeASTM D1003 or manufacturer dataDaylight level and glare
UV protectionSurface film or gelcoat (GRP), co-extruded layer (polycarbonate); yellowing to ASTM E313Durability and light loss over time
Fire classificationIBC CC1 / CC2 via ASTM D635 (US); EN 13501-1 and EN 13501-5 (Europe); AS 1530.3 indices (Australia)Limits on area, spacing and location
Mass or thicknesskg/m² for GRP (about 1.8–3.6), mm for polycarbonateSpan, impact and hail resistance
Fall protectionSafety mesh to local standards (for example AS/NZS 4389); OSHA 1926.501(b)(4) skylight protectionSafe construction and maintenance

Translucent sheets have different thermal expansion from steel, so fixing details (oversized holes, larger washers, no over-tightening) are part of the supply. See skylights and translucent panels.

Documentation, packing and quotation

Deliverables include skylight positions on the roof layout, product data sheets with light transmission and fire classification, fixing details and safety mesh details. Sheets are packed flat with protective interleaving and shipped with the cladding to avoid damage.

A quotation can be prepared quickly when the enquiry states the project location and the code to be used. Please send:

  1. Required daylight area or number of panels per bay.
  2. Roof and wall profile, insulated or uninsulated.
  3. Fire and safety requirements, including safety mesh.
  4. Preferred material and tint.

World Steel returns a priced scope with a clear inclusions and exclusions list, the design basis assumed and a typical lead time. Enquiries go through the export supply team in Ho Chi Minh City.

地域別の規格

地域規格範囲
Australia / NZ AS/NZS 4256Plastic roof and wall cladding materials
Europe EN 1013Light transmitting single skin profiled plastics sheets
Europe EN 14963Continuous rooflights
United States IBC Chapter 26Plastic – light-transmitting plastics
Canada NBC 2020Fire and structural provisions for plastic glazing

よくある質問

How much skylight area is typical?

About 5–10% of the roof area is common for warehouses, but the right figure depends on lighting needs, climate and heat gain.

Can people walk on skylight panels?

No. Translucent sheets are not trafficable; safety mesh or other fall protection is recommended and is required in many markets.

Do skylights match standing seam roofs?

Yes, matching standing seam skylight profiles or curb-mounted skylights are available, subject to the panel system.

次のプロジェクト

海外で鋼構造物をご計画ですか?

図面または IFC モデルをお送りください。積算チームが製作範囲、工程、納入価格をご回答します。