信頼を築き、成功を確かなものに クライアントポータル dang.victor@worldsteelgroup.com +84 902 881 833
World SteelBuilding trust, Assuring success

Building components · Accessories

Doors and framed openings

Doors and framed openings in PEBs: roll-up, sectional, sliding and personnel doors, opening framing, wind design, sizing guidance and installation tips.

更新日 4 分で読めます 3D モデルで見る →

Roll-up door and personnel door in framed openings in a steel building endwall
Framed openings carry door loads and wind into the girts and frames.

Framed openings explained

Every door, window or louver in a pre-engineered building sits in a framed opening: a set of jamb members on each side, a header above and sometimes a sill, which interrupt the girts and transfer wind and door loads into the girts, eave strut, endwall columns or foundations. The door itself is a manufactured product mounted on this framing. Openings are defined at concept stage because they change the wall framing, the bracing layout and sometimes the frame design. Openings left "by others" or cut on site without framing are a common source of cladding damage and leaks.

Exploded view of PEB components including wall girts and openings
Openings interrupt the girts and must be framed back to the structure.

Door types

Common doors in steel buildings
Door typeTypical size rangeCharacteristics
Roll-up (roller shutter) doorUp to about 6 × 6 m standard; larger as specialCurtain coils above the opening; economical; manual chain or motorised
Sectional overhead doorUp to about 8 × 8 mInsulated panels on tracks; good seal; needs headroom for tracks
Sliding doorSingle or bi-parting, very wide openingsHangs from a header track; common in agricultural and hangar buildings
High-speed fabric doorUp to about 5 × 5 m typicalFast cycle for cold stores and logistics traffic
Personnel (man) doorTypically 0.9–1.2 m × 2.1 m, single or doubleSteel leaf in pressed-steel frame; panic hardware for exits
Hangar / bi-fold doorVery largeSpecial structure designed with the frame

Fire-rated doors, insulated doors for cold stores and dock doors with levellers and shelters are specified separately to meet local codes.

Framing and sizing rules

  • Jambs are usually cold-formed C sections for small openings and hot-rolled or built-up members for large doors, spanning from slab to eave strut or to a header.
  • Headers span between jambs and carry wall sheeting above plus the weight of the door coil or track.
  • Clear opening = door size; framed opening is slightly larger to suit the manufacturer's guide and fixing details – obtain door data before detailing.
  • Wind on a closed door is transferred to the jambs and header; a large door may need its own wind columns or a portal frame in the wall.
  • Openings placed in a braced bay require portal bracing instead of rod bracing.
  • Check whether a door may be open during a storm: in many codes a large opening changes the building to "partially enclosed", greatly increasing internal pressure on the whole structure.

Sliding doors, roll-up wind ratings and framed opening types

Sliding doors remain common on PEB because they need no headroom and can close very wide openings. A typical sliding door consists of a leaf framed from cold-formed members and clad with the wall profile, hung from trolleys running in an overhead track fixed to a header, with a bottom guide or floor channel to stop the leaf swinging in the wind. Single-leaf, bi-parting and multi-leaf telescoping arrangements are used; the wall area beside the opening must be long enough to receive the open leaves, and the track header must be designed for the door weight and wind reactions.

Roll-up and sectional doors are rated for wind like any other cladding element. Large curtains deflect inward and outward under wind, and windlocks or end-locks on the slats keep the curtain engaged in the guides. Ratings are established by test:

Wind and impact rating references for large doors
RegionReferenceWhat it covers
United StatesANSI/DASMA 108; ANSI/DASMA 115; ASTM E330Uniform static wind pressure test; wind-borne debris impact; structural test method
Australia / NZAS/NZS 4505Garage doors and other large access doors, including wind loading and cyclonic performance
EuropeEN 13241 with EN 12424 / EN 12444Industrial door product standard; wind-resistance classes 1–5 (300 Pa to above 1,000 Pa) and test method

The required rating comes from the components-and-cladding pressure at the door location. In hurricane and cyclone regions, a door that fails lets the building become internally pressurised, which can overload the roof, so door ratings and the building enclosure classification must be consistent.

Typical framed opening types and members
Opening typeFraming membersNotes
Personnel door openingTwo jambs plus header, often a light C sectionSteel door frame fixed into the jambs
Roll-up or sectional door openingHeavy jambs to eave strut or header, base clips to slabHeader carries the coil or track loads
Sliding door openingJambs, track header, bottom guide channelHeader extends past the opening to carry the open leaves
Window and louver openingJambs between girts, girts as head and sillSill trim with drip
Open bay (no door)Wind column or header girt across the openingCheck partially enclosed design

Personnel doors and frames are commonly specified to ANSI/SDI A250.8 in North America; fire doors are tested and installed to UL 10C and NFPA 80 (US), EN 1634-1 (Europe) or AS 1530.4 with AS 1905.1 (Australia).

Installation and detailing

Jambs are anchored to the slab with expansion or chemical anchors and bolted to the girts or eave strut. Head, jamb and base trims weather-seal the opening (see trims and flashings). Bollards protect jambs from forklift impact. Door guides and brackets must be fixed into framing, not into sheeting. Motorised doors need power and controls coordinated with the electrical contractor. In hurricane and cyclone regions doors should be rated for the design wind pressure and, where required, debris impact.

Maintenance and WSC supply

Check door operation, guides, springs and seals regularly, and repair dents in jambs immediately because they can weaken the opening. World Steel fabricates all framed openings – jambs, headers, sills and trims – as part of the secondary framing, and supplies roll-up and personnel doors in its doors and windows packages, coordinated with windows and louvers on the wall drawings.

地域別の規格

地域規格範囲
United States ANSI/DASMA 108Wind load performance of garage and rolling doors
United States NFPA 80Fire doors and other opening protectives
Canada NBC 2020 Part 3Exits, fire separations and door requirements
Australia / NZ AS/NZS 4505Garage doors and other large access doors
Europe EN 13241Industrial, commercial and garage doors – product standard

よくある質問

Why must large doors be decided before the steel design?

Large openings change the girt and bracing layout, may need wind columns or portal bracing, and can change internal wind pressure assumptions for the whole building.

What is the difference between clear opening and framed opening?

Clear opening is the usable door size. The framed opening is the steel opening, slightly larger to suit guides, coils and fixings specified by the door manufacturer.

Can roll-up doors resist hurricane winds?

Wind-rated roll-up doors with reinforced curtains and guides are available. They should be tested for the project design pressure and, where codes require, for wind-borne debris impact.