Thin-film · cellulosic
Solvent-based intumescent coating
A fast-drying, humidity-tolerant thin-film coating – the usual choice for shop-applied fire protection on export projects.
- Cellulosic (building)
- Fire type
- R30 – R120
- Typical rating
- Interior / sheltered
- Exposure
Supplied by World Steel with your steel building or on its own – one order, one shipment, one partner.
Overview
About Solvent-based intumescent coating
Dries faster than water-based coatings and tolerates higher humidity during application.
Suited to off-site application in the fabrication shop, followed by careful packing.
Topcoated for semi-exposed and humid interior areas.
Key benefits
- Fast drying – practical for shop application and tight schedules
- Better tolerance of humid climates during application
- Robust finish for transport and erection
- Thin film keeps steel slim and visible
World Steel · building envelope hub
How we use Solvent-based intumescent coating in steel buildings
World Steel can apply the primer and intumescent coating in our blasting and painting shop, so members arrive at site already fire-protected – thickness per member from the fire engineer's schedule, recorded in the coating report.
- 01Specified with the structure – thickness, density and facing matched to the roof, wall and fire design.
- 02Quantities taken from the same 3D model as the steel, purlins and cladding.
- 03Packed and shipped with the steel package – one delivery schedule to site.
Applications
Where Solvent-based intumescent coating is used
- Shop-applied protection of beams and columns
- Warehouses, factories and logistics buildings with fire-rated steel
- Semi-exposed steel with approved topcoat
Technical data
Solvent-based intumescent coating – technical properties
Typical properties
| Property | Unit | Value |
|---|---|---|
| Fire curve | — | Standard (cellulosic) |
| Typical rating range | min | 30 – 120 |
| Typical dry film thickness | mm | ≈ 0.3 – 3 (member-specific) |
| Environment | — | Interior and sheltered C2 – C3 with topcoat |
Values as published by the manufacturer for this market. Always check the current data sheet and the approvals required for your project before ordering.
FAQ
Frequently asked questions
What thickness of solvent-based intumescent coating do I need?
It depends on the member size (section factor), the critical temperature and the required fire rating – the fire engineer or the manufacturer's tested data gives a thickness for each member.
Does World Steel supply branded products?
Yes – we supply the brand and listed system your specification or authority requires. This page describes the product type.
One partner for structure and envelope
Send us your drawings or bill of quantities – we quote the steel, insulation, boards and ceilings together and ship them as one package.